A lazy image

Precast Concrete Frame designed and manufactured for Lime Street development

Flood Precast we’re appointed to design, manufacture and the installation of Precast Concrete Frame for BAM Construction at Lime Street in Dublin which consists of two blocks (East Block and West Block) with 217 residential apartments, recreational rooms on the ground floor and a commercial space on the street level.

Originally, the building was designed as a masonry structure combined with concrete poured on the site. BAM contractors along with the design team decided to use prefabricated elements as the main structure of the buildings, therefore the blocks had to be adapted to this type of solution. This posed quite a challenge for the entire project team involved in the project, and finally resulted in the use of mixed construction on the lower levels. Some of the walls and slabs had to be made of concrete poured at the construction site to provide support for prefabricated walls and columns. On the upper floors, due to the limitations in the usable floor space of the apartments, the external walls were made of a light steel structure in combination with prefabricated elements where it was required for construction reasons.

The prefabricated walls are made as full panels with a thickness of 200 mm and 150 mm, while the ceiling slab consists of full prestressed slabs with a thickness of 100 mm and 150 mm of concrete topping.

Thanks to the use of BIM technology, we were able to efficiently solve design problems by participating in coordination meetings and sharing our 3d model with other industries.

Number of floors:7
Area of walls gross/net:East Block: 5956/5260 m2
West Block: 5957/5266 m2
Alltogether: 11 913/10 526 m2
Area of floor per level:East Block: 1184 m2
West Block: 1184 m2
Area of floors for all levels:East Block: 5920 m2
West Block: 5920 m2
Alltogether: 11 840 m2
Volume of concrete used:East Block: 1855 m3
West Block: 1960 m3
Alltogether: 3 815 m3

Project: Lime Street Dublin

Customer: BAM Construction

Engineer:  OCSC Engineering

Architect:  Henry J Lyons

For more information on our range of concrete products contact our team at enquiries@floodprecast.ie